BYQMS - MOLECULAR SIEVE M14

  • MSDS: BYQMS
  • Manufacturer: ZEOCHEM
  • Product Name: MOLECULAR SIEVE M14
  • National Stock Number: 6850-00F045538
Product Identification

Product ID:MOLECULAR SIEVE M14
MSDS Date:06/30/1989
FSC:6850
NIIN:00F045538
MSDS Number: BYQMS

Responsible Party
ZEOCHEM
1314 S 12TH STREET
LOUISVILLE, KY 40232
US

Emergency Phone: 502-634-8384

Info Phone: 502-634-7600

Cage: 3U848

Contractor
ZEOCHEM
35940 LOUISVILLE, KY 40232

Telephone: 502-634-8384

Cage: 3U848

Ingredients

ZEOLITES *95-4*

CAS: 68989-22-0


ZEOLITES, KA

CAS: 68989-21-9


ZEOLITES, NAX

CAS: 68989-23-1


MAGNESIUM ALUMINUM SILICATE

CAS: 1327-43-1

RTECS: VV8880000

Fraction By Weight: 15-25%


SILICON DIOXIDE, CRYSTALLINE QUARTZ, SAND (ANIMAL CARC,

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: 0-2%

OSHA PEL 0.1 MG/CUM RESP DUST

ACGIH TLV: 0.1 MG/CUM RESP DUST

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INGESTION: MAY DAMAGE THROAT/ESOPHAGUS
& GI TRACT. INHALATION: BURNING OF THE UPPER RESPIRATORY
TRACT/TEMPORARY/PERMANENT LUNG DAMAGE. SKIN: PROLONGED/REPEATED
CONTACT MAY CAUSE IRRITATION, DERMATITIS . EYES: MAY CAUSE
IRRITATION, BURNS/CONJUNCTIVITS. CRYSTALLINE SILICA-MAY CAUSE
DELAYED RESPIRATORY DISEASE.
Explanation of Carcinogenicity:SEE INGREDIENTS.
Effects of Overexposure:BURNING, DRYNESS, IRRITATION

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR IMMEDIATELY. IF BREATHING HAS
STOPPED, GIVE CPR. KEEP WARM & AT REST. INGESTION: GIVE EMETICS TO
CAUSE VOMITING. STOMACH SIPHON MAY BE APPLIED AS WELL. MILK & FATTY
ACI DS SHOULD BE AVOIDED. EYES: WASH IMMEDIATELY & CAREFULLY FOR
15-20 MINS W/RUNNING WATER. SKIN: WASH W/SOAP & WATER. OBTAIN
MEDICAL ATTENTION IN ALL CASES. (SEE SUPP)

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:DRY CHEMICAL, WATER SPRAY/FOAM
Fire Fighting Procedures:COOL CONTAINERS THAT ARE EXPOSED TO FLAMES
W/WATER FROM THE SIDE UNTIL WELL AFTER FIRE IS OUT. IN ENCLOSED
AREA, USE UNMANNED HOSE HOLDER/MONITOR NOZZLES.(SUPP)
Unusual Fire/Explosion Hazard:NEGLIGIBLE FIRE & EXPLOSION HAZARD WHEN
EXPOSED TO HEAT/FLAME BY REACTION W/INCOMPATIBLE SUBSTANCES.

Accidental Release

Spill Release Procedures:CLEANUP PERSONNEL NEED PROTECTION AGAINST
INHALATION OF DUSTS/FUMES. EYE PROTECTION IS REQUIRED.
VACUUMING/WET METHODS OF CLEANUP ARE PREFERRED. PLACE IN
APPROPRIATE CONTAINERS FOR DISPOSAL KEEPING AI RBORNE PARTICULATE
AT A MINIMUM.

Handling

Other Precautions:PREVENT REPEATED/PROLONGED SKIN CONTACT.

Exposure Controls

Respiratory Protection:USE A NIOSH/MSHA JOINTLY APPROVED RESPIRATOR IN
THE ABSENCE OF PROPER ENVIRONMENTAL CONTROL/WHERE TLV FOR
CRYSTALLINE SILICA MAY BE EXCEEDED.
Ventilation:GENERAL/LOCAL EXHAUST TO KEEP EXPOSURES VENTILATION MUST BE DESIGNED TO PREVENT DUST ACCUMULATION.
Protective Gloves:REQUIRED
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:PROTECTIVE CLOTHING
Supplemental Safety and Health
FIRE PROC CONT'D: WITHDRAW FROM AREA & LET FIRE BURN IF UNABLE TO
EXTINGUISH. WITHDRAW IMMEDIATELY IF RISING SOUND FROM VENTING
SAFETY DEVICE/ANY DISCOLORATION OF THE TANK DUE TO FIRE. NOTE TO
PHYSICI AN: PRODUCT IS A DESICCANT & GENERATES HEAT AS IT ABSORBS
WATER. CAN CONTAIN HAZARDOUS MATERIAL. TREAT ACCORDINGLY.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:>2900F
Appearance and Odor:PRODUCT MAY APPEAR AS LIGHT TAN BEAD, CAKE/POWDER
Percent Volatiles by Volume:<5%/WT

Stability

Stability Indicator/Materials to Avoid:YES
OLEFINS, HYDROGEN CHLORIDE.
Stability Condition to Avoid:MOISTURE, HIGH CONCENTRATIONS OF CHEMICALS
HAVING HIGH HEATS OF ABSORPTION.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.